Descripción del producto:
The explosion-proof motor has a structure that is different from that used in ordinary environments. It can prevent the combustible gas and dust outside the motor from entering the motor to the maximum extent. Ignite the combustible gas and dust existing in the surrounding environment outside the casing. The electrical equipment cover is housed in a housing with a structure that can withstand the explosive pressure of the internal explosive mixture and can prevent the internal explosion from propagating to the explosive mixture around the housing; making it impossible for the live parts of the motor to cause an explosion hazard Sparks, arcs, or dangerous temperatures, or to isolate live parts that may cause these phenomena from explosive mixtures, so that they cannot contact each other or reach the level of explosive danger. Our company manufacturer generator set for many industries, main products including Perkins Diesel Generator, Mobile Diesel Generator, explosion proof air compressor and so on.
Equipo: |
Generador diesel a prueba de explosiones de 100 kVA |
Instrucciones: |
2014 / 34 / UE - atex |
Estándar: |
En 60079 series / en 1834 series / en 1755 |
Convertir a: |
Equipo del Grupo II, clase 3G (zona 2 IIB T3 GC) |
Generador diesel para la zona de peligro (zona 2), instalado en la carcasa del marco deslizante DNV 2.7-1, salida 100kva @ 0.8 PF, 400vac, tres fases + neutro, 50hz
Modelo |
Eadg100 - ex2 |
Máquina completa |
Signo a prueba de explosiones |
# II 3G IIB T3 GC |
Zona peligrosa |
Región 2 |
Certificado |
A.Declaration of conformity》 |
Salida típica del generador (0,8 PF 25ºC) |
100kva 380v / 50hz |
Ángulo máximo de trabajo |
15° |
Nivel sonoro del ruido (7 m ± 3 DBA) |
75 |
Peso de la máquina (kg) |
2500 (SECO) for reference only |
Dimensiones: l X W X H mm |
3412x2200x2256 sólo para referencia |
Depósito de combustible |
Gt; 300 litros |
Motor diesel |
Fabricante |
Cummins |
Modelo |
6btaa5.9 - G2 |
Velocidad de regulación de velocidad (RPM) |
1500 |
Potencia nominal (kW) |
[email protected] |
Desplazamiento (l) |
5,9 |
Número de cilindros |
6. |
Capacidad de aceite del motor (l) |
18. |
Tensión del sistema eléctrico (V) |
24. |
Capacidad nominal de la batería |
120 amperios |
Generador |
Fabricante |
Kingway OEM |
Signo a prueba de explosiones |
II 3G ex na IIB T3 ip55 |
Número de certificado |
A.Declaration of conformity》 |
Zona peligrosa |
Región 2 |
Temperatura ambiente |
- 25℃ ~ + 60℃ |
Altitud |
≤ 10 millones |
Tensión nominal |
380v (50hz) |
Frecuencia nominal |
50 Hz |
Velocidad nominal |
1500 RPM |
Factor de potencia |
0,8 lager |
Actividades |
Continuo (S1) |
Grado de protección |
Grado de protección: ip55 |
Controlador |
COMAP mrs16 |